Monitoring Interfaces and Transceivers with ethtool

The ethtool command enables you to query or control the network driver and hardware settings and takes the device name, such as swp1, as an argument. When the device name is the only argument, ethtool prints the network device settings. See man ethtool(8) for details.

Monitor Interface Status

cumulus@switch:~$ ethtool swp1 Settings for swp1: Supported ports: [ FIBRE ] Supported link modes: 1000baseT/Full 10000baseT/Full Supported pause frame use: No Supports auto-negotiation: No Advertised link modes: 1000baseT/Full Advertised pause frame use: No Advertised auto-negotiation: No Speed: 10000Mb/s Duplex: Full Port: FIBRE PHYAD: 0 Transceiver: external Auto-negotiation: off Current message level: 0x00000000 (0) Link detected: yes 

The switch hardware includes the active port settings. The output of ethtool shows the port settings in the kernel. The switchd process keeps the hardware and kernel in sync for the important port settings (speed, auto-negotiation, and link detected). However, some fields in ethtool , such as Supported Link Modes and Advertised Link Modes, do not update based on the actual module in the port and might show incorrect or misleading results.

cumulus@switch:~$ ethtool -S swp1 NIC statistics: rx_queue_0_packets: 5 rx_queue_0_bytes: 300 rx_queue_0_drops: 0 rx_queue_0_xdp_packets: 0 rx_queue_0_xdp_tx: 0 rx_queue_0_xdp_redirects: 0 rx_queue_0_xdp_drops: 0 rx_queue_0_kicks: 1 tx_queue_0_packets: 144957 tx_queue_0_bytes: 10546468 tx_queue_0_xdp_tx: 0 tx_queue_0_xdp_tx_drops: 0 tx_queue_0_kicks: 144950 

View and Clear Interface Counters

Interface counters provide information about an interface. You can view this information when you run cl-netstat , ifconfig , or cat /proc/net/dev . You can also run sudo cl-netstat -c to save or clear the interface counters.

cumulus@switch:~$ sudo cl-netstat Kernel Interface table Iface MTU RX_OK RX_ERR RX_DRP RX_OVR TX_OK TX_ERR TX_DRP TX_OVR Flg ------------- ----- ------- -------- -------- -------- ------- -------- -------- -------- ----- lo 65536 185932 0 0 0 185932 0 0 0 LRU eth0 1500 151883 0 0 0 13504 0 0 0 BMRU swp1 9216 5 0 5 0 144986 0 0 0 BMsRU swp2 9216 5 0 5 0 144988 0 0 0 BMsRU swp3 9216 5 0 5 0 144944 0 0 0 BMsRU swp49 9216 502662 0 5 0 502629 0 0 0 BMsRU swp50 9216 507636 0 5 0 507666 0 0 0 BMsRU swp51 9216 749122 0 5 0 794080 0 0 0 BMRU swp52 9216 216057 0 5 0 212567 0 0 0 BMRU bond1 9216 0 0 0 0 144942 0 0 0 BMmRU bond2 9216 0 0 0 0 144944 0 0 0 BMmRU bond3 9216 0 0 0 0 144944 0 0 0 BMmRU br_default 9216 5072 0 0 0 5074 0 0 0 BMRU mgmt 65575 3365 0 0 0 0 0 936 0 OmRU peerlink 9216 1010288 0 0 0 1010295 0 0 0 BMmRU peerlink.4094 9216 506672 0 0 0 506668 0 0 0 BMRU vlan10 9216 1687 0 0 0 1687 0 0 0 BMRU vlan10-v0 9216 1678 0 0 0 1677 0 0 0 BMRU vlan20 9216 1688 0 0 0 1688 0 0 0 BMRU vlan20-v0 9216 1678 0 0 0 1677 0 0 0 BMRU vlan30 9216 1687 0 0 0 1689 0 0 0 BMRU vlan30-v0 9216 1678 0 0 0 1678 0 0 0 BMRU 
cumulus@switch:~$ sudo cl-netstat -c Cleared counters 

Some services, such as MLAG and DHCP can cause drop counters to increment as expected and do not cause a problem on the switch.

Читайте также:  Linux find if program is installed

Monitor Switch Port SFP and QSFP Hardware Information

To see hardware capabilities and measurement information on the SFP or QSFP module in a particular port, use the ethtool -m command. If the SFP or QSFP supports Digital Optical Monitoring (the Optical diagnostics support field is Yes in the output below), the optical power levels and thresholds also show below the standard hardware details. In the sample output below, you can see that this module is a 1000BASE-SX short-range optical module, manufactured by JDSU, part number PLRXPL-VI-S24-22. The second half of the output displays the current readings of the Tx power levels ( Laser output power ) and Rx power ( Receiver signal average optical power ), temperature, voltage and alarm threshold settings.

cumulus@switch$ ethtool -m swp3 Identifier : 0x03 (SFP) Extended identifier : 0x04 (GBIC/SFP defined by 2-wire interface ID) Connector : 0x07 (LC) Transceiver codes : 0x00 0x00 0x00 0x01 0x20 0x40 0x0c 0x05 Transceiver type : Ethernet: 1000BASE-SX Transceiver type : FC: intermediate distance (I) Transceiver type : FC: Shortwave laser w/o OFC (SN) Transceiver type : FC: Multimode, 62.5um (M6) Transceiver type : FC: Multimode, 50um (M5) Transceiver type : FC: 200 MBytes/sec Transceiver type : FC: 100 MBytes/sec Encoding : 0x01 (8B/10B) BR, Nominal : 2100MBd Rate identifier : 0x00 (unspecified) Length (SMF,km) : 0km Length (SMF) : 0m Length (50um) : 300m Length (62.5um) : 150m Length (Copper) : 0m Length (OM3) : 0m Laser wavelength : 850nm Vendor name : JDSU Vendor OUI : 00:01:9c Vendor PN : PLRXPL-VI-S24-22 Vendor rev : 1 Optical diagnostics support : Yes Laser bias current : 21.348 mA Laser output power : 0.3186 mW / -4.97 dBm Receiver signal average optical power : 0.3195 mW / -4.96 dBm Module temperature : 41.70 degrees C / 107.05 degrees F Module voltage : 3.2947 V Alarm/warning flags implemented : Yes Laser bias current high alarm : Off Laser bias current low alarm : Off Laser bias current high warning : Off Laser bias current low warning : Off Laser output power high alarm : Off Laser output power low alarm : Off Laser output power high warning : Off Laser output power low warning : Off Module temperature high alarm : Off Module temperature low alarm : Off Module temperature high warning : Off Module temperature low warning : Off Module voltage high alarm : Off Module voltage low alarm : Off Module voltage high warning : Off Module voltage low warning : Off Laser rx power high alarm : Off Laser rx power low alarm : Off Laser rx power high warning : Off Laser rx power low warning : Off Laser bias current high alarm threshold : 10.000 mA Laser bias current low alarm threshold : 1.000 mA Laser bias current high warning threshold : 9.000 mA Laser bias current low warning threshold : 2.000 mA Laser output power high alarm threshold : 0.8000 mW / -0.97 dBm Laser output power low alarm threshold : 0.1000 mW / -10.00 dBm Laser output power high warning threshold : 0.6000 mW / -2.22 dBm Laser output power low warning threshold : 0.2000 mW / -6.99 dBm Module temperature high alarm threshold : 90.00 degrees C / 194.00 degrees F Module temperature low alarm threshold : -40.00 degrees C / -40.00 degrees F Module temperature high warning threshold : 85.00 degrees C / 185.00 degrees F Module temperature low warning threshold : -40.00 degrees C / -40.00 degrees F Module voltage high alarm threshold : 4.0000 V Module voltage low alarm threshold : 0.0000 V Module voltage high warning threshold : 3.6450 V Module voltage low warning threshold : 2.9550 V Laser rx power high alarm threshold : 1.6000 mW / 2.04 dBm Laser rx power low alarm threshold : 0.0100 mW / -20.00 dBm Laser rx power high warning threshold : 1.0000 mW / 0.00 dBm Laser rx power low warning threshold : 0.0200 mW / -16.99 dBm 

Источник

Читайте также:  Linux mint какая версия ubuntu

Collecting SFP+ attributes in Linux

I need to collect hw component inventory from physical systems running RHEL (6 and 7) and its derivatives. I need to collect the SFP+ attributes along with the rest of the components. I know I can easily get this with ethtool, as long as the interface and the link is up. Is there any way to get this info for all the SFPs from all the ports including those that are down? Thank you in advance.

1 Answer 1

To collect info about plugged modules you can use ethtool —module-info command. This command doesn’t require activation of interface.

Start from this small script:

#!/bin/sh for IFACE in $( ls /sys/class/net/ ) do /sbin/ethtool --module-info $ > /dev/null 2>&1 if [ $? -eq 0 ]; then echo $ /sbin/ethtool --module-info $ fi done exit 0 

Customize it for your needs.

I’m getting ‘Cannot get module EEPROM information. Operation not supported’ when trying to pull this info off the interfaces that do not have a link on. Bringing up an interface at the OS level does not help. It seems to require a link on to be able to get the SFP attributes. Any other suggestions?

Try to update the ethtool. In my systems (various versions of debian) it works perfectly — enough plug in a SFP module into a network card. pastebin.com/3q0DnGtv

This is very interesting. I have the same version, and now I’m wondering if this depends on the NIC support. So far I have tried this only with the Solarflare. You seem to be using Intel. Have you come across any other method of pulling this data from the NIC without relying on ethtool?

Читайте также:  Сервер сетевой загрузки линукс

Depends on what data you want to collect. But the SFP module properties can be get only through driver of NIC, because these values are gotten through internal i2c bus on NIC. So details of this process is implemented in the driver. Maybe in your case this data can be found somewhere in /sys filesystem without call of the ethtool .